Service
Substation maintenance
Maintenance and integration of MV and HV substations up to 230 kV: breakers, protection, instrument transformers and documented commissioning.

A substation is a system of systems: the power transformer, breakers, instrument transformers, boards, protection and the grounding and control infrastructure. Maintaining it well means going through all of them in order, not just the most visible one.
Our scope covers the power transformer (oil, bushings, electrical tests), the breakers (contact resistance, timing, simultaneity and insulation resistance, on vacuum and oil units), the boards and cells (cleaning, re-torque, insulators, interlocks), and the protection and control (relay testing, instrument transformers, batteries, coordination).
Everything is executed under safety procedures (lockout/tagout, verification of de-energization, temporary grounding), and closes with a documented protocol by component.
What we maintain
Primary equipment
Power transformer, breakers, disconnectors, instrument transformers and busbars.
When it applies: Scheduled substation maintenance.
Protection & control
Relay testing, instrument transformers, control batteries and coordination.
When it applies: Verification of protection functions.
Predictive, preventive and corrective substation maintenance
| Type | Equipment condition | What is done | What it decides |
|---|---|---|---|
| Predictive | Energized for thermography and visual inspection; oil sample in service only where safe; breaker results from previous outages | Thermography, transformer oil analysis and breaker test trends | Which equipment is serviced first, and in which outage window |
| Preventive | Scheduled outage | Breaker mechanism, contact resistance and timing; relay testing; cleaning, re-torque and interlocks in boards and cells | Documented condition by component for the next cycle |
| Corrective | Outage | Correction of the findings from inspection and testing | Equipment restored, with closing values in the protocol |
How we execute the service
Safety
Lockout/tagout, verification of de-energization and temporary grounding.
Inspection & testing
Component-by-component checklist with precision instrumentation.
Intervention
Cleaning, re-torque and correction of findings.
Protocol
Documented report by component with recommendations.
Frequently asked questions — substation maintenance
How often should an MV substation be maintained?
The schedule must be documented against the manufacturer's instructions, asset condition and trends, load, environment, history and failure consequences. Engineering must justify the program and reassess it when anomalies appear; this page does not prescribe a universal interval.
What is checked on the breakers?
Contact resistance (ducter), opening and closing times, simultaneity between poles and insulation resistance, on vacuum and oil breakers.
Why include thermography?
It detects loose connections and hot spots with the equipment energized, before the outage, prioritizing where to intervene.
What is predictive substation maintenance?
Deciding what to service from measured condition and its trend, not only from the calendar: thermography with the equipment energized, power-transformer oil analysis (sampled in service only where the valve can be reached safely) and breaker contact-resistance and timing results from previous outages. Preventive work then executes, under outage, what those measurements prioritize, and corrective work addresses the findings.
Do you test the protection?
Yes: relays are verified and, where applicable, tested by secondary injection; instrument transformers, control batteries and protection coordination are reviewed.
Substation maintenance in images






Related services
Talk to a transformer specialist
Tell us about your asset so we can define the assessment scope and prepare a tailored quote.