Substation maintenance

Maintenance and integration of MV and HV substations up to 230 kV: breakers, protection, instrument transformers and documented commissioning.

Bushings being installed with crane support on a transformer in a substation yard
What the photo showsBushings being installed with crane support on a transformer in a substation yard.

A substation is a system of systems: the power transformer, breakers, instrument transformers, boards, protection and the grounding and control infrastructure. Maintaining it well means going through all of them in order, not just the most visible one.

Share the nameplate data and the condition you observe; we reply with the proposed scope.

Our scope covers the power transformer (oil, bushings, electrical tests), the breakers (contact resistance, timing, simultaneity and insulation resistance, on vacuum and oil units), the boards and cells (cleaning, re-torque, insulators, interlocks), and the protection and control (relay testing, instrument transformers, batteries, coordination).

Everything is executed under safety procedures (lockout/tagout, verification of de-energization, temporary grounding), and closes with a documented protocol by component.

What we maintain

Primary equipment

Power transformer, breakers, disconnectors, instrument transformers and busbars.

When it applies: Scheduled substation maintenance.

Protection & control

Relay testing, instrument transformers, control batteries and coordination.

When it applies: Verification of protection functions.

Predictive, preventive and corrective substation maintenance

TypeEquipment conditionWhat is doneWhat it decides
PredictiveEnergized for thermography and visual inspection; oil sample in service only where safe; breaker results from previous outagesThermography, transformer oil analysis and breaker test trendsWhich equipment is serviced first, and in which outage window
PreventiveScheduled outageBreaker mechanism, contact resistance and timing; relay testing; cleaning, re-torque and interlocks in boards and cellsDocumented condition by component for the next cycle
CorrectiveOutageCorrection of the findings from inspection and testingEquipment restored, with closing values in the protocol

How we execute the service

Safety

Lockout/tagout, verification of de-energization and temporary grounding.

Inspection & testing

Component-by-component checklist with precision instrumentation.

Intervention

Cleaning, re-torque and correction of findings.

Protocol

Documented report by component with recommendations.

Frequently asked questions — substation maintenance

How often should an MV substation be maintained?

The schedule must be documented against the manufacturer's instructions, asset condition and trends, load, environment, history and failure consequences. Engineering must justify the program and reassess it when anomalies appear; this page does not prescribe a universal interval.

What is checked on the breakers?

Contact resistance (ducter), opening and closing times, simultaneity between poles and insulation resistance, on vacuum and oil breakers.

Why include thermography?

It detects loose connections and hot spots with the equipment energized, before the outage, prioritizing where to intervene.

What is predictive substation maintenance?

Deciding what to service from measured condition and its trend, not only from the calendar: thermography with the equipment energized, power-transformer oil analysis (sampled in service only where the valve can be reached safely) and breaker contact-resistance and timing results from previous outages. Preventive work then executes, under outage, what those measurements prioritize, and corrective work addresses the findings.

Do you test the protection?

Yes: relays are verified and, where applicable, tested by secondary injection; instrument transformers, control batteries and protection coordination are reviewed.

Substation maintenance in images

Technician in orange coveralls working a hot stick above a power transformer in a substation yard
Technician in orange coveralls working a hot stick above a power transformer in a substation yard
Substation yard with a power transformer and its steel structure, seen against the light
Substation yard with a power transformer and its steel structure, seen against the light
Worker manoeuvring on the equipment beside an insulator stack in a substation yard
Worker manoeuvring on the equipment beside an insulator stack in a substation yard
Two workers between the bushings of a transformer with crane support
Two workers between the bushings of a transformer with crane support
Three workers on the bushings and surge arresters of a transformer
Three workers on the bushings and surge arresters of a transformer
Technician pressure-washing substation equipment amid clouds of water vapour
Technician pressure-washing substation equipment amid clouds of water vapour